BUNN Axiom display errors, decoded

Applies to: BUNN Axiom series (ICB similar but strings unverified)

What this error means

BUNN's digital office brewers announce faults in documented plain-English strings: 'HEATING TIME TOO LONG' (tank heater, thermistor, or control board — or a water-supply problem), 'FILL TIME TOO LONG' (water shut off, supply line, inlet solenoid), 'TEMP SENSOR OUT OF RANGE' (probe or wiring — service item), and an escalating series of lime warnings from 'CHECK SPRAYHEAD FOR LIME' up to 'WARNING VERY LOW FLOW – PLEASE REPAIR.' Note 'TEMPERATURE TOO LOW' isn't a fault — it's the brew lockout while the tank reheats.

Symptoms

  • Error string on the display
  • Brew lockout
  • Lime warnings appearing

Try this first (safe DIY steps)

  1. FILL TIME TOO LONG: check the water shutoff valve and supply line first — usually external
  2. Lime warnings: run the deliming spring procedure (see our weak-coffee guide) and clean the sprayhead before assuming failure
  3. TEMPERATURE TOO LOW: wait — it's heating
  4. Log the exact string for the service call if it persists

Safety: power off before any physical intervention. Never bypass covers or interlocks — fuser areas run hot enough to burn.

When to call a technician

HEATING TIME TOO LONG and TEMP SENSOR OUT OF RANGE are meter-and-parts diagnoses — service tech or a confident DIYer with the service manual.