Trane furnace 3 flashes — Pressure switch error
Applies to: Trane gas furnaces (American Standard same platform)
What this error means
The draft pressure switch is open when it should be closed (or closed when it should be open). Causes: blocked vent or intake (check the exterior termination — snow and ice are seasonal classics), a failing draft inducer, or on condensing furnaces a blocked condensate drain.
Symptoms
- No ignition; inducer may run continuously
- 3-flash pattern on the status LED
Try this first (safe DIY steps)
- Check and clear the exterior vent/intake termination
- On high-efficiency models, check the condensate drain isn't clogged or frozen
- Power off 30–60 seconds and restore
Safety: power off before any physical intervention. Never bypass covers or interlocks — fuser areas run hot enough to burn.
When to call a technician
If it returns with clear venting: pressure switch ($150–$400) or inducer motor ($400–$1,100 installed) diagnosis.