FixOffice
DIY fix — no technician neededVerified by FixOffice

Automatic faucet stopped working

Applies to: Sloan, Moen, Delta and similar sensor faucets

What this error means

The documented causes, in order: dead or low batteries (Sloan's low-battery signature is an intermittently flashing red LED; Moen specifies checking installation and using alkalines), a dirty or obstructed sensor lens (including protective stickers never removed after install — genuinely documented), and the same clogged aerator that afflicts manual faucets. No water at all with good batteries points to the solenoid valve.

Symptoms

  • No response to hands
  • Intermittent red LED (battery warning)
  • Weak dribble (aerator, not sensor)

Try this first (safe DIY steps)

  1. Replace the batteries first (under-sink control box or spout base; alkaline only)
  2. Wipe the sensor lens clean; check for leftover protective film
  3. Clean the aerator (see the aerator guide)
  4. Check the under-sink supply stops are fully open
  5. Still dead: the solenoid — part is replaceable on commercial models

Safety: power off before any physical intervention. Never bypass covers or interlocks — fuser areas run hot enough to burn.

When to call a technician

Solenoid replacement or hardwired/transformer models beyond battery-and-lens basics — plumber or the manufacturer's parts line.

Get new repair guides as we publish them

One short email when we add equipment you care about. Optionally tell us what's broken in your office right now — it directly sets our roadmap.