Commercial toilet keeps flushing / won't shut off (Sloan-type flushometer)

Applies to: Sloan Royal/Regal-class flushometers (Zurn similar)

What this error means

Per Sloan's own troubleshooting documentation, a flushometer that runs continuously has a diaphragm problem: the bypass hole in the diaphragm assembly is clogged with debris (wash it under running water) or the diaphragm/relief valve is worn — replace the kit. The first response is always the control stop: the shutoff under the chrome cap beside the valve (flathead slot or vandal-resistant key) — turn clockwise to stop the water and end the flood while you sort out parts.

Symptoms

  • Water running continuously after flush
  • Repeating flush cycles
  • Water bill quietly doubling

Try this first (safe DIY steps)

  1. Stop the water: pop the control-stop cap, turn the screw clockwise until flow stops (newer stops may need the special key — it lives in the maintenance drawer)
  2. Confident DIYers: shut the stop, relieve pressure by triggering the valve, open the cover, remove the diaphragm assembly, wash the bypass hole clean, reassemble
  3. Persisting: replace the diaphragm kit — matched to the valve's GPF label (see our kit guide)

Safety: power off before any physical intervention. Never bypass covers or interlocks — fuser areas run hot enough to burn.

When to call a technician

A plumber's flushometer rebuild visit runs roughly $150–350; the kit itself is $15–55, and the job is 15 minutes with the water off — facilities-savvy offices DIY this one.