FixOffice
DIY fix — no technician neededVerified by FixOffice

Lennox E250 — Limit switch circuit open

Applies to: Lennox E-code era furnaces (EL/SL series)

What this error means

The high-temperature limit opened — the furnace overheated, and if the limit doesn't reclose within 3 minutes the control takes a 1-hour soft lockout. Same story as every brand's limit code: it's almost always airflow (dirty filter, blocked returns, dirty coil or blower).

Symptoms

  • Short-cycling heat
  • E250 displayed
  • Weak airflow at registers

Try this first (safe DIY steps)

  1. Fresh, correct-spec filter; open registers; clear returns
  2. Power off 30 seconds and restore (or wait out the 1-hour lockout)
  3. If it recurs with good airflow, stop resetting

Safety: power off before any physical intervention. Never bypass covers or interlocks — fuser areas run hot enough to burn.

When to call a technician

Persistent E250 despite airflow fixes = blower/coil service or limit switch replacement ($150–$400).

Get new repair guides as we publish them

One short email when we add equipment you care about. Optionally tell us what's broken in your office right now — it directly sets our roadmap.